OCSA=0, OCSAD=0, TSSAD=0, TSSA=0
A/D Conversion Extended Input Control Registers
TSSAD | Temperature Sensor Output A/D-Converted Value Addition/Average Mode Select 0 (0): Do not select addition/average mode for temperature sensor output. 1 (1): Select addition/average mode for temperature sensor output. |
OCSAD | Internal Reference Voltage A/D-Converted Value Addition/Average Mode Select 0 (0): Do not select addition/average mode for internal reference voltage. 1 (1): Select addition/average mode for internal reference voltage. |
TSSA | Temperature Sensor Output A/D Conversion Select 0 (0): Disable A/D conversion of temperature sensor output 1 (1): Enable A/D conversion of temperature sensor output |
OCSA | Internal Reference Voltage A/D Conversion Select 0 (0): Disable A/D conversion of internal reference voltage 1 (1): Enable A/D conversion of internal reference voltage |